Equipment for combined therapy - one channel for 1/3 MHz ultrasound therapy and electro therapy with 2 independent channels and 25 wave forms. In ultrasound therapy, a sensor allows the energy to be supplied only when there is contact with the patient, sending the operator a visual and auditory feedback. In electrotherapy, instead, the microcontrollers to the power boards verify in real time that the selected current is deliver correctly and report any possible anomalies.
Display 320x240. Smart card included.
ACCESSORIES SUPPLIED
TECHNICAL SPECIFICATIONS - ELECTROTHERAPY
Programmable treatment time: Up to 60 minutes
Operation: Low frequency, Medium frequency
Waveforms: 25 families of waveforms, 32 total waveforms
Operation: Constant voltage, Constant current
Peak current (Load resistance 1KOhm)
- Pulsed currents: 100 mA
- Diadynamic currents: 70 mA
- Continue currents - IONOPHORESIS: 50 mA
Peak voltage (Load resistance 1KOhm)
- Pulsed currents: 100 V
- Diadynamic currents: 70 V
- Continue currents - IONOPHORESIS: 50V
Stored protocols: 25
Storable protocols in the user memory: 100
Storable curve I/t in the user memory: 100
Storable protocols in the smart-card: 50
Storable curve I/t in the smart-card: 20
Storable curve I/t in the smart-card: 2 independent
Treatment with electrotherapy |
Current | |
1) |
ARTHRITIS |
Bifasic |
2) |
BURSITIS |
Galvanic |
3) |
CARPAL TUNNEL SYNDROME |
Tens burst |
4) |
CERVICAL ARTHROSIS |
Interferenztial |
5) |
CHELOIDS |
Iontoforesi |
6) |
DORSAL PAIN |
Tens |
7) |
EPICONDYLITIS |
Tens |
8) |
EPITROCLEITIS |
Tens |
9) |
FIBROMYALGIA |
Interferential |
10) |
HIP PERIARTHRITIS |
Tens |
11) |
METATARSALGIA |
Short perios |
12) |
MUSC RHEUMATISM |
Interferential |
13) |
MUSC SPASMS/CONTRACTIONS |
Galvanic |
14) |
NEURALGIAS |
Classic Interferential |
15) |
PERI-ARTICULAR CALCIFICATIONS |
Galvanic |
16) |
POST-SURGICAL PAIN |
Tens burst |
17) |
PUBALGIA |
Interferential |
18) |
RHEUMATOID ARTROSIS |
Classic Interferential |
19) |
SEQUENTIAL DRAINAGE ARMS |
Kotz |
20) |
SEQUENTIAL DRAINAGE-LEGS |
Kotz |
21) |
SCIATIC PAIN |
Tens |
22) |
SHOULDER PERIARTRITIS |
Interferential |
23) |
SKULL DISEASE |
TENS |
24) |
TENDINOSIS |
Tens |
25) |
TENDINOSIS |
Long perios |
TECHNICAL SPECIFICATIONS - ULTRASOUND THERAPY
Programmable treatment time: Up to 30 minutes
Emission Frequency: 1 MHz e 3 MHz
Adjustable Duty-Cycle: ( 10 – 100 ) %
Duty Cycle adjustable frequency: ( 10 – 100 ) Hz
Continue peak power: 2 W / cm² ± 20%
Pulsed peak power: 3 W / cm² ± 20%
Stored protocols: 25
Storable protocols in the user memory: 100
Storable curve I/t in the smart-card: 50
Output channels: 1
TREATMENT WITH ULTRASOUND THERAPY
TECHNICAL SPECIFICATIONS - COMBINED THERAPY
Programmable treatment time: Up to 99 minutes
Current type: Low frequency, Medium frequency
Emission frequency: See the electro-therapy and ultrasound section
Adjustable Duty-Cycle: See the ultrasound section
Continue peak power: See the ultrasound section
Pulsed peak power: See the ultrasound section
Stored protocols: 20
Outputs channels: 2 independents
TREATMENT WITH COMBINED THERAPY