This new device, unlike the Tecar and Endotherapy electro-medical devices, allows the physiotherapist to use simultaneously two treatment methods, combining the resistive/capacitive energy transfer and the diffusion of the active agent (where prescribed by the physician), with a hand piece called ROLL-ON (patented).
CAPACITIVE MODE
The warming sensation generated inside the body depends on various factors, and can be perceived by the patient at intensities that range from warmth to intense internal heat. When using capacitive electrodes, the diameter of the electrode and speed of movement must be considered in particular. For the same amount of power applied, larger diameter electrodes increase the temperature more gradually and, in addition, the faster the electrode is moved, the less the heat sensation felt by the patient.
Gastrocnemius treatment example - CAPACITIVE MODE
The operator transfers energy and medicines into the patient’s gastrocnemius muscle .The effect will be hypervascularization of tissue, and consequently its filling with oxygen, nourishing factors, enzymes on the arterial side, and drainage of catabolites on the venous side.
It is good practice to choose the electrode with the largest area possible in relation to the area to be treated. The electrode can be applied, both staying still in the area treated and using circular or linear movements, depending on the area treated and power you wish to apply. It is very important that most of, if not all of, the electrode’s area be in contact with the patient’s skin, following any curves and irregularities in the area treated, and continuously adapting to it. The electrode holder handgrip is specifically designed to minimise effort on the part of the operator and to make the treatment more pleasant for the patient (deep massage action, as if the electrode were an “extension of the operator’s hands”).
MANUAL MODE WITH DIRECT - RESISTIVE COUPLING
Direct coupling means using the TCARE Cellular Regenerator with uninsulated metal electrodes (no dielectric device interposed). The action mechanism, caused by polarity reversal of the current, produces a quicker and more intense increase in heat in tissue deprived of water and electrolytes (bone tissue and adipose tissue especially). This application method is therefore more indicated, perhaps along with the capacitive mode, for pathologies involving these parts of the body. Since the active electrode is not insulated, the current that moves the charges and the temperature generated in the body are less concentrated in the area immediately below the active electrode, producing a directional aspect guided by the passive electrode (return plate).
Knee treatment example - RESISTIVE MODE:
The operator gets the patient to move their knee into flexion/extension to concentrate Tcare action in the inflamed zone and gain a wider range of motion (.e.g. knee collateral ligament)
In other words, one substantial difference from the capacitive mode lies in taking great care when positioning the return electrode, which directs impulses generated by the active electrode. Another difference is that the active electrode remains in a set position or slight rotational movements are made with a diameter slightly larger than that of the electrode used, and continually adjusting the power applied so that the temperature perceived by the patient is pleasant.
THERAPEUTIC INDICATIONS:
BIOLOGICAL EFFECTS OF THE TREATMENT:
ACCESSORIES SUPPLIED:
EL0147 - Mini Capacitive ROLL-ON 40 mm
EL0163 - Mini Resistive ROLL-ON 40 mm
EL0113 - Capacitive ROLL-ON 80 mm
EL0129 - Resistive ROLL-ON 80 mm
EL0122 - Passive plate
EL0164 - Medium Capacitive ROLL-ON 56 mm
EL0165 - Medium Resistive ROLL-ON 56 mm
AC0665 - Elastic band, cm 60
AC0667 - Elastic band, cm 100
EL0148 - Dispenser with cap
EL0128 - Ball cap
EL0149 - Mini dispenser
EL0125 - Passive plate lubrication cream 1000 ml
EL0124 - ROLL-ON lubrication cream 500 ml
HOW DOES THE ROLL-ON HANDPIECE WORK
The special patented handpiece, known as the ROLL-ON, means that the TCARE Cellular Regenerator device guarantees the best geometric application for achieving capacitive-resistive energy transfers. The particular shape of the handpiece provides an extensive contact area between the electrode and the patient’s skin, while the ROLL-ON’s functionality ensures that, unlike traditional handpieces, the correct quantity of cream is released at the contact interface on a real-time basis. This is sufficient to guarantee the development of the electro-chemical gradient, without allowing any dielectric arc to be formed. It also makes it possible to avoid wasteful dispersion of conductive cream, which provides significant savings in the operating costs sustained by professionals that use the device.